Double pilot operated non-return valve for 12 mm articulated mounting (DIN 2353)

Double pilot operated non-return valve for 12 mm articulated mounting (DIN 2353)
Instructions for use:
Pilot-operated check valves are used to block actuators in both directions, allowing fluid flow in one direction and blocking fluid flow in the opposite direction until pressure is applied. They can be easily installed in cylinders. On request, accessories are available for installation at a specific center distance of the cylinder.
Application:
Connect V1 and V2 to pressure flow and C1 and C2 to articulated actuators.
Specifications | 3/8”L 2 CC | 1/2”L 2 CC |
Pilot ratio | 1:5.5 | 1:5 |
Maximum flow(L/min) | 35 | 50 |
Maximum pressure(Bar) | 350 | |
Opening pressure(Bar) | 3 |



Model | V1/V2 | C1/C2 | L | L1 | L2 | L3 | L4 | M | H | S |
HYVBPDE3/8”L 2 CC | G3/8” | 12L | 80 | 150 | 38 | 180 | 96 | M8 | 40 | 30 |
HYVBPDE1/2”L 2 CC | G1/2” | 15L | 90 | 164 | 45 | 196 | 106 | M8 | 45 | 35 |