Single pilot operated check valve for 12 mm pipe mounting (DIN 2353)

Single pilot operated check valve for 12 mm pipe mounting (DIN 2353)
Instructions for use:
Pilot operated check valves are used to block the cylinder in one direction, allowing fluid to flow in one direction and blocking the flow in the opposite direction until pressure is applied.
Can be easily mounted on the cylinder. Accessories are available on request for mounting at a specific center distance of the cylinder.
Application:
Connect V1 and V2 to the pressure flow, C1 to the free flow side of the actuator and C2 to the side of the actuator that you want to block.
Specifications | 1/4”L 2 CEXC | 3/8”L 2 CEXC | 1/2”L 2 CC |
Pilot ratio | 1:5.5 | 1:5.5 | 1:5 |
Maximum flo(L/min) | 20 | 30 | 50 |
Maximum pressur(Bar) | 350 | ||
Opening pressure(Bar) | 4 | 4 | 3 |



Model | V1/V2 | C1/C2 | L | L1 | L2 | L3 | L4 | M | H | S |
HYVBPSE1/4”L 2 CEXC | G1/4” | 12L | 64 | 134 | 36 | 160 | 84 | M8 | 40 | 30 |
HYVBPSE3/8”L 2 CEXC | G3/8” | 12L | 64 | 134 | 36 | 166 | 84 | M8 | 40 | 30 |
HYVBPSE1/2”L 2 CC | G1/2” | 15L | 90 | 164 | 45 | 196 | 106 | M8 | 45 | 35 |